7.5 Hp (5.5 KW) AC Line Reactor, 3 Phase Input
from
$299.36
Ex Tax: $299.36
- Stock: In Stock
- Model: RDDLZ-ILR-5d5
- Weight: 1.00
- SKU: RDDLZ-ILR-5d5
Available Options
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
5.5 kW AC vfd line reactor, 3 phase input, voltage optional 220V, 380V, 400V, 460V and 480V. It is widely used in various power supply places with a frequency of 50Hz/60 Hz and is worth your choice.
7.5 hp Input Line Reactor Specifications
Basic | Model | RDDLZACR-0015-0M94-0.4SC |
Recommended VFD Model | GK3000-4T0055G (7.5 hp three phase VFD) | |
Phase | 3 Phase | |
Power | 7.5 hp (5.5 kW) | |
Weight | 3 kg | |
Technical Parameters | Work Valtage | 380V (optional: 220V/ 240V/ 400V/ 415V/ 440V/ 460V/ 480V) |
Work Frequency | 50Hz/60 Hz | |
Rated Current | 15 A | |
Max Current | 1.5 Times the Rated Current, Continued 60s | |
Inductance Value | 0.94 mH | |
Material | Aluminium/Copper (Optional) | |
Voltage Drop | 2% | |
Noise | ≤65dB | |
Insulation Class | Class F, H | |
Protection Class | IP00-IP22 | |
Insulation Resistor | ≥100MΩ | |
Working Environment | Operation Environment | -10℃~+45℃ |
Temperature Rise | ≤85K | |
Humidity | ≤90%RH, without condensation | |
Running Ambient Temperature | -25℃~+45℃ | |
Altittude | ≤2000m |
7.5 hp Input Line Reactor Size & Circuit Diagram
Dimension (±5mm) | |||||
L | D | W | W1 | H | A×B |
115mm | 90mm | 95mm | 68mm | 135mm | 6×11 |
Tips:
Reactors have a variety of functions to improve the reactive power, including:
- Capacitance effect on light airborne or lightly loaded lines to reduce power frequency transient overvoltage.
- Improve the voltage distribution on long-distance transmission lines.
- Make the reactive power in the line as light as possible on the light load, prevent the irrational flow of reactive power and reduce the power loss on the line.
- When the large unit is in parallel with the system, reduce the steady-state voltage of the power frequency on the high-voltage bus, so that the generators can be juxtaposed at the same time.
- Prevent self-excitation resonance phenomenon that may occur in the long line of the generator.
- When the neutral point of the reactor is used to pass the small reactance grounding device, the small reactor can also be used to compensate the phase and phase capacitance of the line to accelerate the automatic extinguishing of the submerged current, which is convenient to adopt.
Builder in Product TAB
NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc.
You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.
Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.