- Stock: In Stock
- Model: RDDLZ-ERT-30k
- Weight: 1.00
- SKU: RDDLZ-ERT-30k
Available Options
Soil resistivity tester for sale online. It is also a earth resistance tester that can measure ground resistance, soil resistivity, and ground voltage on-site, available with a 0~30000 ohm large range, reading, consulting, saving, reporting, printing and other historical data functions, widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection and industrial electrical equipment.
Features
- Soil resistivity tester is available with a 0.00~30kΩ measure range and a waterproof case.
Digital soil resistivity tester has a precise 3/4-wire and simple 2-wire method to measure earth resistance, soil resistivity and earth voltage. - It has imported FFT (fast Fourier transform) technology, and AFC (automatic frequency control) technology, with unique anti-interference ability and environmental adaptability, high repeat test consistency.
- Package with waterproof protection box, waterproof, crash-proof, anti-drop and durable, and large-capacity rechargeable lithium battery pack, especially suitable for use at outdoor construction sites.
- The soil resistivity tester is equipped with a large LCD display of the host machine with a white backlight and bar graph indication that can be seen clearly. Alarm function, overload protection function, auto shutdown and data upload function.
Specifications
Model | RDDLZ-ERT-3100C | ||
Earth Resistance(R) | Range: 0.00Ω~30.00Ω Resolution: 0.01Ω Accuracy: ±2%rdg±3dgt | ||
Range: 30.0Ω~300.0Ω Resolution: 0.1Ω Accuracy: ±2%rdg±3dgt | |||
Range : 300Ω~3000Ω Resolution: 1Ω Accuracy: ±2%rdg±3dgt | |||
Range: 3.00kΩ~30.00kΩ Resolution: 10Ω Accuracy: ±4%rdg±3dgt | |||
Earth Voltage | Range: AC 0.0~600V Resolution: 0.1V Accuracy: ±2%rdg±3dgt | ||
Soil Resistivity(ρ) | Range: 0.00Ωm~99.99Ωm Resolution: 0.01Ωm | Accuracy: According to the precision of R (ρ=2πaR, a: 1 m-100m, π=3.14) | |
Range: 100.0Ωm~999.9Ωm Resolution: 0.1Ωm | |||
Range: 1000Ωm~9999Ωm Resolution: 1Ωm | |||
Range: 10.00kΩm~99.99kΩm Resolution: 10Ωm | |||
Range: 100.0kΩm~999.9kΩm Resolution: 100Ωm | |||
Range: 1000kΩm~9000kΩm Resolution: 1kΩm | |||
Power Supply | DC 7.4V 2600mAh rechargeable lithium battery, full charge about DC 8.4V | ||
Measurement Method | Earth Resistance: rated current change-pole method, measure current 20mA Max Soil Resistivity: Wenner 4-pole measurement Earth Voltage: average rectification(between P(S)-ES) | ||
Test Frequency | 128Hz/111Hz/105Hz/94Hz (AFC) | ||
Test Voltage Wave | Sine wave | ||
Short-circuit Test Current | AC 20mA max | Open-circuit Test Current | AC 40V max |
Data Storage | 300 groups | Data Hold | Data hold function: "HOLD" symbol display |
Data Access | Data access function: "READ" symbol display | Overflow Display | Exceeding measure range overflow function: "OL" symbol display |
LCD Dimension | LCD Frame Dimension: 128mm×75mm; LCD Display Dimension: 124mm×67mm | ||
Tester Dimension | 280mm(L)×260mm(W)×160mm(H) | ||
Weight | Total Weight: 5700g(with package) | ||
Testing Wires | Red 20m, black 20m, yellow 10m, green 10m, red 1.6m, black 1.6m (total 6pcs wires) | ||
Auxiliary Ground Rod | 4PCS: Φ10mm×250mmp10mmx250mm | ||
USB Interface | With a USB interface, software monitoring, stored data can be uploaded to a computer, saved and printed, data transmission cable length: 1.5m | ||
Alarm Function | Measure value exceeds alarm setting value, will "Toot-toot-toot" alarm indication | ||
Auto Shutdown | 15 minutes after power is on, will automatically shut down without any operation. | ||
Overload Protection | Measure earth resistance: between each interfaces of C(H)-E, P(S)-ES, AC 280V/3 seconds | ||
Interference Test | Automatic recognition of interference signal, interference voltage higher than 5V will display the "NOISE" symbol | ||
Auxiliary Grounding Test | Auxiliary earth resistance test function: 0.00kΩ~30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ) | ||
Protection Level | IP65(close the case) | ||
Battery Voltage | When the battery voltage decreases to around DC 7.2V+0.1V, will display the battery voltage low symbol, and remind to replace the battery | ||
Working Current | Standby: around 20mA (Backlight close); Power on with backlight: 45mA (backlight close 25mA); Measurement: 100mA (Backlight close) | ||
Accessories | Tester: 1PC; Ground Rod: 4PCS; Test wires: 4PCS; Simple test wire: 2PCS; USB data transmission cable: 1PCS; Tester bag: 1PCS; Special charger: 1PCS |
Note: The additional error when rCmax or rPmax is ≤ ± 3% rdg ± 5dgt.
Details
Applications
RDDLZ provides earth resistance testers with a measurement range of 0.00Ω-300kWΩ, which are widely used in ground resistance measurement and loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil fields, construction, and industrial electrical equipment. When measuring the grounding system with a loop, the ground resistance tester does not need auxiliary electrodes and does not need to disconnect the grounding wire, which is safer and faster.
Tips: Do we need to test soil resistivity regularly?
It depends on whether your current or future needs require soil resistivity testing as it will determine the type of ground resistance tester you need. For example, if your work involves the design or installation of a new grounding system, soil resistivity testing is a must. Currently, most people use a ground resistance tester to test soil resistivity.