DC current sensor has measuring range of 400A/500A/1000A/2000A/3000A/5000A/8000A/10000A to 20000A.
Specification:
Model | RDDLZ-AHKC-KAA | RDDLZ-AHKC-HBAA |
Shipping weight | 1kg | |
Hole size * | 64*16mm | 132*52mm |
Measuring range of input current * | DC 0-400A ~ 0-2000A | DC 0-2000A ~ 0-20000A |
Output signal | DC 4-20mA | |
Zero offset current | ±0.05mA | |
Offset current drift | ±0.04mA/℃ | |
Linearity | ≤0.2%FS | |
Power supply * | DC 24V±10% or DC 12V±10% | |
Accuracy | 1.0%F.S. | |
Response time | ≤1ms | |
Withstand voltage | AC 2500V (between input, output and power supply) | |
Work temperature | -25~+70℃ | |
Storage temperature | -40~+85℃ | |
Humidity | ≤95%RH (no dew formation, no corrosive gas) | |
Elevation | ≤3500m | |
Measuring method | Split-core type | |
Installation | Screw fixation |
400A to 20000A DC current sensor dimensional diagram:
Model | Dimension (mm) | |||||
W | H | D | a | e | N (Mounting) | |
RDDLZ-AHKC-KAA | 127 | 63 | 25 | 64 | 16 | 30 |
RDDLZ-AHKC-HBAA | 204 | 111.5 | 29 | 132 | 52 | 48*2 |
400A to 20000A DC current sensor wiring diagram:
Tips: 5 attentions for AC/DC current sensor
- The current sensor must properly select different measuring range based on the rated effective value of the current under test. The long time excess of the rated current will damage the last stage power amplifier tube (refer to the magnetic compensation current sensor). In general, the time of duration of double overload current must not exceed 1 minute.
- AC/DC current sensor with insulation voltage resistance of 3KV can work for a long time in 1KV and below AC systems and 1.5KV and below DC systems, current sensor with 6KV can work for a long time in the 2KV and below AC systems and 2.5KV and below DC systems, be careful not to use under overvoltage.
- When applying high-current DC system, it is worth noting for the core produces a larger residual magnetism which caused by the power supply open circuit or fault. Residual magnetism affects accuracy. The method of demagnetization is to connect an alternating current and gradually reduce the value of the original current without connecting a power supply.
- The current sensor's ability to resist external magnetic field is: The distance of two 2000A current sensors is 5~10cm, the current value is more than twice original current, the resulting magnetic field interference can be resisted. When the three-phase large current sensor is wiring, the interphase distance should be greater than 5~10cm.
- The primary coil temperature must not exceed 85 ℃, which is determined by the characteristics of ABS Engineering Plastics. High-temperature plastic for the shell can be customized.
Builder in Product TAB
NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc.