- Stock: In Stock
- Model: RDDLZ-LDS-PDACC85
- Weight: 1.00
- SKU: RDDLZ-LDS-PDACC85
Available Options
Features
- Exquisite appearance and light aluminum housing, easy to mount and dismount.
- Convenient operation panel with visualized OLED display to complete all function settings fastly.
- Small diameter light spot to accurately measure very tiny objects.
- Key or remote teach-in to easily set response time for different applications.
- Powerful function setting and flexible output way.
- Complete shielded desgin, stronger anti-interference perfomance.
- IP67 protection degree, able to work in water or dusty environment.
Specification
Model | RDDLZ-PDA-CC85DGR | RDDLZ-PDA-CC85TGI |
Linear Accuracy | ±0.3% F.S | ±0.4% F.S |
Supply Voltage | 10-30V DC | 12-24V DC |
Output Signal | RS-485 (Support Modbus protocol) | 4-20mA (Load resistance< 390Ω) |
Connection | 2m 5-pins/ 4-pins PVC cable | 4-pin: analog output |
Light Source | Red laser (650nm) | |
Laser Class | Class 2 | |
Spot Diameter | Φ0.5@85mm | |
Measuring Center Distance | 85mm | |
Measuring Range | ±25mm | |
Resolution | 30um@85mm | |
Repeated Accuracy | 60um | |
Voltage Drop | <2.5V | |
Power Consumption | ≤ 700mW | |
Load Current | 200mA | |
Circuit Protection | Short circuit, reverse polarity, overload protection | |
Ambient Temperature | -10-50℃ | |
Temperature Drift | ±0.04% F.S./℃ | |
Response Time | 2ms/ 16ms/ 40ms (configurable) | |
Ambient Humidity | 35-85% RH (No condensation) | |
Anti-ambient Light | Incandescent light: <3,000lux | |
Impluse Withstand | 500m/s² (About 50G)3 times each in X, Y, Z directions | |
Vibration Resistance | 10-55Hz Double amplitude 1mm, 2h each in X ,Y, Z directions | |
Protection Degree | IP67 | |
Material | Housing: Aluminum; Lens cover: PMMA; Display panel: PC | |
Accessory | Screw (M4×35mm)×2, Nut×2, Washer×2, Mounting bracket, Operation manual | |
Dimension | 65*51*23mm | |
Certificates | CE, UL, CCC, ROHS | |
Warranty | 12 months |
Remark:
①Test conditions: Standard data at 23 ± 5 ℃; Supply voltage 24V DC; 30 minutes' warmup before test; Sampling period 2ms; Average sampling times 100; Standard sensing object 90% white card.
②The statistical data follows the 3σ criteria
③Repeat accuracy: 23 ± 5 ℃ environment, 90% reflectivity white card,100 test data results.
④Slave address,baud rate setting only for RS-485 series.
⑤Protecion circuit only for switch output.
Dimension (unit=mm)
Accessory Dimension
Wiring diagram
Remark:
The sensors are equipped with shielded cables, Q is the switch output.
RS-485 output: The black and white lines A and B must not be reversed and A and B cannot be short-circuited with the power line "﹢, -".
Analog output: The gray line Ia cannot be short-circuited with the power line "﹢, -". There is a small shielded wire, which shall not be in short-circuit connection with the analog output wire, but recommended to be grounded or not grounded.
Installation of laser distance sensor
Tips: Safety Warning of Laser Distance Sensor.
- Do not use in an environment with flammable,explosive or corrosive gases.
- The RS485 communication line should not be too long.
- Do not disassemble,repair or modify this product without authorization.
- This product is dangerous, please do not look directly at the laser or observe the optical system through the lens.