- Stock: In Stock
- Model: RDDLZ-DPS-30
- Weight: 1.00
- SKU: RDDLZ-DPS-30
Available Options
Factory price digital air pressure switch featuring withstand pressure 500kPa- 1.5MPa, ±1% F.S. high acuuracy. The pressure switch is widely used in factory automation, chemical textile industry, medical equipment, chemical industry and other fields.
Features
- Numbers are displayed in 2 colors.
- Space-saving installation.
- Digital pressure switch can be copied to 10 pressure switches at the same time.
Specification
Model | RDDLZ-NZSE30A | RDDLZ-NZSE30AF | RDDLZ-NISE30A | ||
Rated pressure range | 0.0~101.0kPa | -100.0~100.0kPa | -100.0~1.000MPa | ||
Display/ Set pressure range | 10.0~105.0kPa | -105.0~105.0kPa | -105.0~1.050MPa | ||
Withstand pressure | 500kPa | 500kPa | 1.5MPa | ||
Display/ Minimum unit setting | 0.1kPa | 0.1kPa | 0.001MPa | ||
Switch output | Output types | NPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs | |||
Maximum load current | 80mA | ||||
Maximum applied voltage | 28 V (at NPN output) | ||||
Residual voltage | 1 V or less (with load current of 80 mA) | ||||
Response time | 2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms) | ||||
Short circuit protection | Yes | ||||
Hysteresis | Hysteresis mode | Variable (0 or above) | |||
Window comparator mode | |||||
Analog output | Voltage output | Output voltage (Rated pressure range) | 1~5V ± 2.5% F.S. | 1~5V ± 2.5% F.S. | |
Linearity | ±1% F.S. | ||||
Output impedence | Approx. 1kΩ | ||||
Current output | Output voltage | 4~20mA±2.5% F.S | 2.4~20mA±2.5% F.S. | ||
Linearity | ±1% F.S. | ||||
Load impedance | Maximum load impedance: Power supply voltage 12V: 300Ω, Power supply voltage 24V: 600Ω Minimum load impedance: 50Ω | ||||
Environment | Enclosure | IP40 | |||
Operating temperature range | Operating: –5 to 50°C, Stored: –10 to 60°C (No freezing or condensation) | ||||
Operating humidity range | Operating and stored: 35 to 85% RH (No condensation) | ||||
Withstand voltage | AC1000V for 1 minute between terminals and housing | ||||
Insulation resisitance | 50MΩ or more (500 VDC measured via megohmmeter) between terminals and housing | ||||
Fluid | Air, Non-corrosive gas, Non-flammable gas | ||||
Takeover diameter | Rc1/ 8 | ||||
Power supply voltage | 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With power supply polarity protection) | ||||
Current consumption | 40 mA or less | ||||
Repeatability | ±0.2% F.S.±1 digit | ||||
Display | 4-digit, 7-segment, 2-color LCD (Red/Green) | ||||
Display accurancy | ±2% F.S. ±1 digit (at 25°C ±3°C ambient temperature) | ||||
Indicator light | Lights up when output is turned ON. OUT1: Green; OUT2: Red | ||||
Lead wire with connector | ±2% F.S. (at 25°C in an operating range of -5 to 50°C) | ||||
Temperature characteristics | ±2% F.S. (25°C reference) | ||||
Lead wire | Oilproof heavy-duty vinyl cable, 3 cores ø3.5, 2 m 4 cores; Conductor area: 0.15 mm2 (AWG26); Insulator O.D.: 1.0 mm | ||||
Standards | CE, UL/ CSA, RoHS |
Internal Circuits and Wiring
Dimension (mm)
Details
Tips: Digital Pressure Switch Working Principle.
The digital pressure switch is mainly used to detect the pressure of the relevant detection part. It works by sensing the pressure of the external environment through built-in sensors. When the external pressure value exceeds or falls below the safety critical point, the sensor membrane changes, and then a control signal is sent to guide the switch to change. Therefore, when the ambient pressure returns to normal and critical, the inner membrane of the sensor will move to the original position, making the switch reset automatically, and then detect the medium pressure signal through the special CPU modular signal processing technology.