10 Hp (7.5 KW) Air Compressor Motor, 208-230V, 1-3/8" Shaft
from
$1,212.25
Ex Tax: $1,212.25
- Stock: In Stock
- Model: RDDLZ-ACM10
- Weight: 1.00
- SKU: RDDLZ-ACM10
Available Options
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Buy 3600rpm 7.5kW air compressor motor at affordable price. 213/ 5T frame, steel housing, insulation class is F. It can be used for metal cutting, machine tools, water pumps, blowers, transportation machinery, agricultural machinery, etc.
Specification
Model | RDDLZ-CM102215T |
Power | 10 HP (7.5 kW) |
Speed | 3600 rpm |
Current | 48-46 A |
Voltage | 208-230 V |
Protector | × |
Frame | 213/ 5T |
Shaft diameter | 1-3/8" |
Shaft length | 3.38" |
Capacitance | 2 |
ENC | ODP |
Frequency | 60Hz |
IP | 23 |
INS | F |
ROT | CW/ CCW |
Housing material | Steel plate |
Packing size | 60*38*42cm |
Weight | 46kg |
Dimention (Unit: inch)
Details
Tips: Air compressor motor troubleshooting - the motor current is too high
- The air compressor motor temperature controller is faulty, and the temperature controller needs to be replaced.
- The overload protector is faulty, and the overload protector needs to be replaced.
- The air inlet is blocked and needs cleaning and maintenance.
- The drive belt tension is too tight. Loosen the transmission belt, the normal tension of the air compressor is 0.8-1.0cm downward pressure.
- The air filter is blocked and needs to be replaced (when the vacuum value is greater than 5psi).
- The starter contacts are in poor contact, and the starter contacts need to be maintained.
- The oil and gas separator is blocked, and the oil and gas separator needs to be replaced (when the pressure difference is greater than 0.8-1kg).
- If the motor bearing is not oiled, it is necessary to add grease to the motor bearing.
- If the ambient temperature is too high, it is necessary to install ducted exhaust equipment.
- Three-phase voltage is unstable, lack of phase, and voltage is too low (less than 10%). It is recommended to improve the power system.
- The motor bearing is damaged, and the motor needs to be removed for insulation strengthening.
- The motor insulation is poor, and the motor bearings need to be replaced.
- The motor wiring is loose, and the motor wiring needs to be re-locked.
Builder in Product TAB
NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc.
You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.
Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.