Your Cart
We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.
Free shipping all orders over on $200
30 days easy and hassle-free returns
24/48h Customer support available

Portable Methane (CH4) Gas Detector, 0 To 100% Vol

Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
Portable Methane (CH4) Gas Detector, 0 To 100% Vol
from
$2,046.87
Ex Tax: $2,046.87
  • Stock: In Stock
  • Model: GD200-CH4
  • Weight: 1.00
  • SKU: GD200-CH4

Available Options

Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.

Portable Methane (CH4) gas detector comes with infrared mathene sensor, built-in micro pump and measuring range 0-100% VOL, fast response and accurate measurement, long service life and favorable price.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof

Specification

ModelGD200-CH4
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleInfrared
GasMethane (CH4)
Range (Optional)*0 to 100% LEL, 0 to 50% VOL, 0 to 100% VOL
Resolution1% LEL (0-100% LEL), 0.01% VOL (0-50% VOL, 0-100% VOL)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
CommunicationMini USB interface supports standard MODBUS communication protocol
Explosion-proof GradeⅡ 2G Ex ia Ⅱ CT4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note:
* If you need a CH4 gas detector with other measuring ranges unlisted in above table, please contact us to inform your operating environment, so as to help you choose an appropriate one for your application.
* We also provide other common gas detectors, and you can refer to RDDLZ Gas Detector Catalog to get the specific gas type and measurement range. If you have any questions, please feel free to contact us.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Applications

Portable Methane gas detector, pump-suction type, adopts infrared methane gas sensor for CH4 concentration detection and it's widely applied in gas station, gas pipeline leak detection, Methane pipeline purity measurement, laboratories or some confined spaces, etc.

Tips: To prevent mine gas explosion, why only detect methane?

Methane is an organic compound with a molecular formula of CH₄ and a molecular weight of 16.043. It is the main component of natural gas, biogas, pit gas or mine gas, etc. Methane is a flammable gas, and it is extremely explosive after being ignited. Therefore, it is necessary to install flammable gas alarms and fire-fighting equipment to detect the gas composition and concentration in the environment at any time, such as methane in a mine.

The composition of mine gas is very complex. Its important component is methane (CH4), followed by carbon dioxide (CO2) and nitrogen (N2). It also contains a small or trace amount of heavy hydrocarbon gases (ethane, propane, butane, pentane, etc.), Hydrogen (H2), Carbon Monoxide (CO), Sulfur Dioxide (SO2), Sulfurizer (H2S), etc.

Among the gas components of mine gas, only methane gas will explode after exceeding the lower explosion limit, and other gases such as CO and H2S are toxic gases, which will only harm the human body and will not explode. Gases such as CO2, N2 are inert gases and usually only affect the oxygen content. Therefore, in terms of preventing explosion hazards, detecting methane is sufficient. The portable methane detector can detect the methane concentration in the environment in real time, and the detector will give the sound and light alarm when the concentration exceeds the standard.The combustible gas detector also need be installed in a working environment where combustible gas is easy to produce and leak so as to control the risk within a controllable and safe range. Other gas types and concentrations can also be measured with corresponding detectors.

Write a review

Note: HTML is not translated!
Rating
Bad Good

Builder in Product TAB

NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules. Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.