Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm

Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
Fixed Nitrogen Dioxide (NO2) Gas Detector, 0 To 100/500/1000 Ppm
from
$734.87
Ex Tax: $734.87
  • Stock: In Stock
  • Model: GD300-NO2
  • Weight: 1.00
  • SKU: GD300-NO2

Available Options

Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.

High-quality fixed nitrogen dioxide gas detectors with self-calibration and zero calibration functions, make the detection more accurate and reliable. Measuring ranges of 0-20, 0-50, 0-100, 0-500, 0-1000ppm, with temperature compensation for gas concentration under condensing conditions. The infrared controller can remotely control the gas alarm setting, and the gas leak detector can output one or two switching signals, which can drive the ventilator or solenoid valve and other external devices. Adopting original overseas gas sensors, it is compatible with various controlled alarms, PLC, DCS, and other control systems, and can be remotely monitored.

Features

  • Adopting high precision sensor for accurate gas leak detection.
  • Equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • Compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • With self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • Can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-NO2
Detection PrincipleElectrochemistry
GasNitrogen Dioxide (NO2)
Range (Optional)0 to 1ppm, 0 to 5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 500ppm, 0 to 1000ppm
Resolution0.001ppm(0-1/5ppm), 0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm) 1ppm (0-500/1000ppm)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeⅡ 2G Ex ia Ⅱ CT4 Ga
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12-36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
AccessoriesPower adapter: Input 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug or UK plug)

Note: To measure confined spaces such as pipelines, please contact us and inform the detailed conditions of use.

Fixed Gas Detector Dimension (Unit: mm)

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Tips: Fixed Nitrogen Dioxide (NO2) Gas Detector Working Principle

  1. Chemical or Electrochemical Sensors: Fixed NO2 gas detectors typically use chemical or electrochemical gas sensors as the core component to detect the presence and change in concentration of NO2 gas.
  2. Gas Sampling: Gas leak detectors typically introduce a sample of ambient air into the gas sensor via a gas sampling system. This can be accomplished through a pumping system, pump, or other sampling device.
  3. Potential Measurement: Once NO2 gas enters the sensor, a catalytic reaction at the working electrode causes a change in potential. The electrode circuitry measures this potential change and converts it into an electrical signal.
  4. Signal Processing and Data Output: Gas tester typically include signal processing circuitry to amplify, filter and stabilize the signal obtained from the sensor. Finally, the gas detector outputs the measured NO2 concentration data in digital form, usually presented to the user via a display, data logging system, communications interface, etc.
  5. Calibration: To ensure accurate measurements, fixed NO2 gas detectors usually require periodic calibration. This can be done by using a known concentration of calibration gas.

Write a review

Note: HTML is not translated!
Rating
Bad Good

Builder in Product TAB

NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules. Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.