6000VA 120V/220V UPS Backup Uninterruptible Power Supply

6000VA 120V/220V UPS Backup Uninterruptible Power Supply
6000VA 120V/220V UPS Backup Uninterruptible Power Supply
6000VA 120V/220V UPS Backup Uninterruptible Power Supply
6000VA 120V/220V UPS Backup Uninterruptible Power Supply
6000VA 120V/220V UPS Backup Uninterruptible Power Supply
6000VA 120V/220V UPS Backup Uninterruptible Power Supply
6000VA 120V/220V UPS Backup Uninterruptible Power Supply
from
$2,077.69
Ex Tax: $2,077.69
  • Stock: In Stock
  • Model: RDDLZ-UPS-6K
  • Weight: 1.00
  • SKU: RDDLZ-UPS-6K

Available Options

Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.

Applications

6000VA/4800 Watts high-performance UPS with battery backup provides an uninterruptible power source for the loaded equipment or devices with optional input and output voltages of 220V/120V AC, and the UPS power supply is widely used for personal computers, office equipment, test equipment, light system, safe alarm system, ray equipment, medical equipment, copy machine, numerical control machine tools, industrial automation equipment, color and drying equipment, Hi-Fi equipment, etc.

6kVA UPS Specification

BasicsModelRDDLZ-BE-6K
Rated Capacity6000VA/4800W
PhaseSingle Phase (L, N, G) * NOT support the split phase (L1, L2 + G) like USA standard.
Weight (kgs)12
Dimensions (mm)369×190×318
InputNominal Voltage208/220/230/240VAC
Input Voltage Range110-300 VAC (Based on load at 50%), 176-300 VAC (Based on load at 100%)
Frequency Range46-54 Hz or 56-64 Hz
Power Factor≥0.99 @ Nominal Voltage (100% load)
OutputOutput Voltage208/220/230/240VAC
Voltage Regulation±1%
Frequency Range (Synchronized Range)46-54 Hz or 56-64 Hz
Current Crest Ratio50 Hz or 60 Hz ±0.1Hz
Harmonic Distortion≤3% THD (Linear Load), ≤5% THD (Non-linear Load)
Transfer TimeZero
Waveform (Batt. Mode)Pure Sinewave
EfficiencyAC Mode92%
Battery Mode90%
BatteryBattery TypeDepending on the capacity of external batteries
Numbers16 - 20 (Adjustable)
Charging Current (Max.)1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)
Charging Voltage273 VDC 土1% (Based on 20pcs batteries)
IndicatorsLCDLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
AlarmBattery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinuously sounding
EnvironmentHumidity0-95% RH @ 0-50°C (non-condensing)
Noise LevelLess than 55dB @ 1 Meter
ManagementSmart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser

Note:

1. The UPS input/output configuration is 1-phase (L, N, G) like Europe standard, NOT support the split phase (L1, L2 + G) like USA standard.

2. Batteries that work with this UPS are not included, customers need to match lead-acid battery packs on their own, consult us for battery specifications.

3. If you need other output voltage range, please contact us.

Rear Panel Diagram

  1. External battery connector
  2. RS-232 communication port
  3. Intelligent slot
  4. USB communication
  5. Emergency power off function connector (EPO connector)
  6. Cooling fan
  7. Input circuit breaker
  8. Input/ Output terminal (Refer to Diagrams 3 and 6 for the details)

Tips: UPS troubleshooting - there is no display on the panel and the UPS does not work after the starting up.

Judging from the phenomenon, it is the fault of the electric power supply input, battery, and electric supply detection and battery voltage detection circuit.

1. Check whether the electric power supply input fuse is burned out.

2. Check whether the UPS battery fuse is burned out and whether the electric supply input fuse is OK. Because the UPS output and display will be shut down when some UPS cannot detect battery voltage.

3. Check whether the electric supply detecting circuit is working normally and if the UPS battery fuse is OK. If it doesn’t work normally and UPS doesn’t have a starting-up function without an electric supply, UPS output and display will be shut down. If the electric supply detecting circuit is working normally, please check whether the UPS battery voltage-detecting circuit is normal.

Write a review

Note: HTML is not translated!
Rating
Bad Good

Builder in Product TAB

NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules. Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.