Your Cart
We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.
Free shipping all orders over on $200
30 days easy and hassle-free returns
24/48h Customer support available

4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge

4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
4-Step/5-Step Calibration Block For Ultrasonic Thickness Gauge
from
$238.09
Ex Tax: $238.09
  • Stock: In Stock
  • Model: RDDLZ-UT-B
  • Weight: 1.00
  • SKU: RDDLZ-UT-B

Available Options

Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.

Calibration blocks for ultrasonic thickness gauge are available with 4 step, 5 step, 6 step and 10 step in millimeter and inch.

Calibration Block Specification

ModelItemParameterSizeMaterial
RDDLZ-B-101-00014 step calibration block3mm 5mm 10mm 15mm80 x 20mm1018 Steel
RDDLZ-B-101-00120.100” 0.200” 0.400” 0.600”3.15 x 0.7in1018 Steel
RDDLZ-B-101-00020.250” 0.500” 0.750” 1.000”3.15 x 0.8 inch1018 Steel
RDDLZ-B-101-00135 step calibration block5mm 10mm 15mm 20mm 25mm100 x 20mm1018 Steel
RDDLZ-B-101-00030.100” 0.200” 0.300” 0.400” 0.500”4 x 0.8 inch1018 Steel
RDDLZ-B-101-00046 step calibration block1mm 3mm 5mm 10mm 15mm 20mm120 x 20mm1018 Steel
RDDLZ-B-101-00052.5mm 5mm 10mm 15mm 20mm 25mm120 x 20mm1018 Steel
RDDLZ-B-101-000610 step calibration block1mm 2mm 3mm 4mm 5mm 6mm 7mm 8mm 9mm 10mm200 x 20mm1018 Steel
RDDLZ-B-101-00072mm 4mm 6mm 8mm 10mm 12mm 14mm 16mm 18mm 20mm200 x 20mm1018 Steel
RDDLZ-B-101-00080.100” 0.200” 0.300” 0.400” 0.500” 0.600” 0.700” 0.800” 0.900” 1.000”8 x 0.8 inch1018 Steel
RDDLZ-B-101-00095 step calibration block2.5mm 5mm 10mm 15mm 20mm100mm1018 Steel

Tips: Why you need a calibration block for ultrasonic thickness gauge?

The ultrasonic thickness gauge is used to accurately measure the thickness of different materials under different conditions. In order to meet the requirements of the maximum accuracy measurement, a set of reference test blocks or calibration block will be very important. The closer the material of the calibration block is to the material to be tested, the more accurate the measurement. The ideal reference test block is a set of test pieces of different thicknesses of the material to be tested. The calibration block can offer the UT instrument compensation correction factors.

In most cases, using one calibration block can obtain satisfactory measurement accuracy. This reference test block should have the same material and similar thickness as the tested material.

For thin materials, when its thickness is close to the lower limit of probe measurement, the calibration block can be used to determine the exact lower limit. Do not measure materials below the lower limit of thickness. If a thickness range can be estimated, the upper limit should be chosen for the thickness of the calibration block.

As for the thick material to be tested, especially for alloys with complex internal structures, the one among the reference block that is close to the tested material should be selected, so as to facilitate calibration.

Write a review

Note: HTML is not translated!
Rating
Bad Good

Builder in Product TAB

NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules. Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.