Your Cart
We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.
Free shipping all orders over on $200
30 days easy and hassle-free returns
24/48h Customer support available

300 KVA Isolation Transformer, 3 Phase, 480V To 400V

300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
Free Shipping
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
300 KVA Isolation Transformer, 3 Phase, 480V To 400V
from
$30,086.16
Ex Tax: $30,086.16
  • Stock: In Stock
  • Model: RDDLZ-T-SG300KVA
  • Weight: 1.00
  • SKU: RDDLZ-T-SG300KVA

Available Options

Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.

Three phase 300 kVA isolation transformer offers consistent, smooth voltage transformation at 480V AC input, 480V to 400V version or 400V to 480V is available, and other voltages can be customized.

Generally, isolation transformers with power above 150KVA will be equipped with an alarm, which is used to detect the temperature of the transformer. When the temperature of the transformer rises to 150 degrees, the alarm will be triggered. At this time, the transformer needs to be manually suspended or stopped. Wait until the transformer temperature returns to normal, then continue to use.

300 kVA Isolation Transformer Specifications

BasicsModelRDDLZ-SG300KVA
Phase3 phase
Capacity300 kVA
Weight of Aluminium Wire TransformerOpen type: 740kg
Protected type: 890kg
Weight of Copper Wire TransformerOpen type: 930kg
Protected type: 1005kg
Technical ParametersPrimary Voltage480V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage400V (Optional: 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 22
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:
Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

3 Phase Isolation Transformer Details

300 kVA Isolation Transformer Installation Dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=1060**450*955mmOpen type: a*b*c=990**410*855mm
Mouting size: d*e=600*400mmMouting size: d*e=600*400mm
Protected type: A*B*C=1300*750*1600mmProtected type: A*B*C=1300*750*1600mm

Tips: Using isolation transformer to reduce the zero voltage of UPS

For medium and small power UPS, generally, an isolation transformer is installed at its output part; for a three-in to three-out high-power UPS, the transformer is usually at its bypass input. This method can eliminate the problem that zero voltage is low before the UPS powering on while zero voltage rises after UPS turning on. The UPS power system makes no negative impact on the power grid and load through this method.

Write a review

Note: HTML is not translated!
Rating
Bad Good

Builder in Product TAB

NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules. Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.