Your Cart
We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.
Free shipping all orders over on $200
30 days easy and hassle-free returns
24/48h Customer support available

Portable Oxygen (O2) Gas Detector, 0 To 30% Vol

Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
Portable Oxygen (O2) Gas Detector, 0 To 30% Vol
from
$479.22
Ex Tax: $479.22
  • Stock: In Stock
  • Model: GD200-O2
  • Weight: 1.00
  • SKU: GD200-O2

Available Options

Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.

Portable O2 gas detector is used to monitor 0 to 30% Vol or 100% Vol oxygen concetration, widely used for laboratories, research institutions, vehicle battery industry, confined space and so on.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof.

Specification

ModelGD200-O2
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasOxygen (O2)
Range (Optional)*0 to 25% VOL, 0 to 30% VOL, 0 to 100% VOL
Resolution0.01% VOL
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
CommunicationMini USB interface supports standard MODBUS communication protocol
Explosion-proof GradeⅡ 2G Ex ia Ⅱ CT4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note:
* If you need a O2 gas detector with other measuring ranges unlisted in above table, please contact us to inform your operating environment, so as to help you choose an appropriate one for your application.
* We also provide other common gas detectors, and you can refer to RDDLZ Gas Detector Catalog to get the specific gas type and measurement range. If you have any questions, please feel free to contact us.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Tips: How to Choose the Measuring Range of Oxygen Gas Detector?

Oxygen concentration in the air is 20.9%VOL. Checking whether the oxygen content is up to the standard or not, we generally select an oxygen (O2) detector with a range of 0~20%VOL or 0~30%VOL. Such a measuring range can meet most demands, and it’s also the most common range. RDDLZ portable oxygen detector is avaliable for 0 to measuring range of 30% Vol to meet the most common requirements.

In some cases, the oxygen concentration will also be tested, such as testing the purity of oxygen in oxygen bottle, then an oxygen detector with a range of 0~100%VOL is chosen. The precision can be customized, which is generally 0.1%VOL and 0.01%VOL. As for the special case that oxygen concentration is far below the normal value, such as the anaerobic incubator and smoke, the oxygen concentration is quite low, thus a range of 0~5%VOL is generally selected.

Write a review

Note: HTML is not translated!
Rating
Bad Good

Builder in Product TAB

NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules. Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.