Fixed Hydrogen Chloride (HCl) Gas Detector, 0 To 10/20/50/100/200 Ppm
from
$1,062.99
Ex Tax: $1,062.99
- Stock: In Stock
- Model: GD300-HCL
- Weight: 1.00
- SKU: GD300-HCL
Available Options
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
RDDLZ fixed HCL hydrogen chloride gas detector uses high quality sensors, and advanced micro-process technology, with data display and high/low alarm, fast response, high precision and good stability. Explosion proof, suitable for different kinds of situations.
Specification
Model | GD300-HCL |
Detection Principle | Electrochemistry |
Gas | Hydrogen Chloride (HCl) |
Range (Optional) | 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 200ppm |
Resolution | 0.01ppm (0-10/20/50ppm), 0.1ppm (0-100/200ppm) |
Calibration Kit | Gas pressure regulator (calibration gas cylinder NOT included) |
Accuracy | ≤±3% F.S. |
Response Time | ≤10s |
Repeatability | ≤±1% |
Recovery Time | ≤10s |
Linearity Error | ≤±1% |
Zero Shift | ≤±1% (F.S./year) |
Signal Output (Optional) | 4-20mA and RS485 Relay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional). |
Alarms | Sound, light |
Display | High light nixie tube display |
Installation | Wall-mounted, piping type, flow-type (according to the detected environment) |
Connection | Power connection type: G1/2 male thread explosion-proof flexible pipe Pipe-mounted type: M45*P2.0 |
Operating Time | 24h |
Explosion-proof Grade | Ⅱ 2G Ex ia Ⅱ CT4 Ga |
Protection Grade | IP65 |
Certification | CE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014) |
Working Voltage | 12-36V DC |
Case Material | Die-casting aluminum housing |
Operating Temperature | -20℃~50℃ |
Operating Humidity | 0~95%RH (non-condensing) |
Dimension | 206*179*90mm |
Weight | ≤1.6kg |
Accessories | Power adapter: Input 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug or UK plug) |
Note: To measure confined spaces such as pipelines, please contact us and inform the detailed conditions of use.
Fixed Gas Detector Dimension (Unit: mm)
***Other Common Gases and Ranges Available for Fixed Gas Detectors
Gas Type | Measure Range | Resolution |
Ammonia (NH3) | 0-50/100/200/500/1000/2000/5000ppm | 0.01ppm/0.1ppm/1ppm |
Benzene (C6H6) | 0-1/10/50/100/200/1000/2000/5000/10000ppm | 0.001ppm/0.01ppm/0.1ppm/1ppm |
Carbon Dioxide (CO2) | 0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL | 0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL |
Carbon Monoxide (CO) | 0-10/20/50/100/500/1000/2000ppm | 0.01ppm/0.1ppm/1ppm |
Chlorine (Cl2) | 0-5/10/20/50/100ppm | 0.001ppm/0.01ppm/0.1ppm |
Chlorine Dioxide (ClO2) | 0-1/5/10/20/50/100ppm | 0.001ppm/0.01ppm/0.1ppm |
Combustible Gas (EX) | 0-100%LEL | 1%LEL |
Ethylene (C2H4) | 0-10/20/50/100/500/1000/2000ppm | 0.01ppm/0.1ppm/1ppm |
Formaldehyde (CH2O) | 0-10/20/50/100/500/1000ppm | 0.01ppm/0.1ppm/1ppm |
Hydrocarbons (HC) | 0-100%LEL | 1%LEL |
Hydrogen (H2) | 0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL | 0.1ppm/1ppm/0.001%VOL/1%LEL |
Hydrogen Chloride (HCL) | 0-10/20/50/100/200ppm | 0.01ppm/0.1ppm |
Hydrogen Cyanide (HCN) | 0-10/20/50/100ppm | 0.01ppm/0.1ppm |
Hydrogen Sulfide (H2S) | 0-5/20/50/100/200ppm | 0.001ppm/0.01ppm/0.1ppm |
Methane (CH4) | 0-50/100%VOL, 0-100%LEL | 0.01%VOL/0.1%VOL/1%LEL |
Nitric Oxide (NO) | 0-1/5/10/20/50/100/250/500/1000ppm | 0.001ppm/0.01ppm/0.1ppm/1ppm |
Nitrogen (N2) | 0-99.99/0-100%VOL | 0.01%VOL/0.1%VOL |
Nitrogen Dioxide (NO2) | 0-1/5/10/20/50/100/500/1000ppm | 0.001ppm/0.01ppm/0.1ppm/1ppm |
Nitrogen Oxides (NOX) | 0-1/5/10/20/50/100/250/500/1000ppm | 0.001ppm/0.01ppm/0.1ppm/1ppm |
Oxygen (O2) | 0-25/30/100%VOL | 0.01%VOL/0.1%VOL |
Ozone (O3) | 0-1/5/10/20/50/100ppm | 0.001ppm/0.01ppm/0.1ppm |
Phosphine (PH3) | 0-10/20/50/100/500/1000/2000/3000ppm | 0.01ppm/0.1ppm/1ppm |
Sulfur Dioxide (SO2) | 0-1/5/10/20/50/100/500/1000ppm | 0.001ppm/0.01ppm/0.1ppm/1ppm |
Volatile Organic Compounds (VOC) | 0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm | 0.001ppm/0.01ppm/0.1ppm/1ppm |
Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.
Details
Application
Tips for installing a fixed gas detector
- Wiring should be done in the case of power failure, and the power should be turned on after confirming that the wiring is correct; the probe should be debugged by remote control when it is determined that there is no gas leakage on site.
- The installation location should be within a radius of 1 meter near the valve, pipe interface, air outlet or the place where it is easy to leak, as close as possible, but do not affect the operation of other equipment.
- When used for large-area gas detection, a probe can be arranged in 20-50 square meters, which can achieve the effect of safety monitoring.
- Installation height: When detecting gases lighter than air such as hydrogen, natural gas, city gas, etc., it is installed at a distance of about 1 meter above the roof; when detecting gases heavier than air such as liquefied petroleum gas, it is installed at a distance of 1.5-2 meters below the ground. Install about meters.
- The installation method can be roof hoisting, wall hanging or connecting pipes, etc. It should be ensured that the installation is firm and reliable. We are equipped with an infrared remote control to facilitate debugging and operation.
- The on-site wiring should be put through pipes, the pipes used should meet the fire protection requirements, and the pipes should be connected with the probe to meet the fire protection requirements.
- When installing, the sensor should be fixed downward.
- Shielded cables should be used for wiring. The diameter of a single wire is greater than 1 square millimeter. The shielding layer must be grounded when wiring.
Builder in Product TAB
NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc.
You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules.
Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.