Your Cart
We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.
Free shipping all orders over on $200
30 days easy and hassle-free returns
24/48h Customer support available

Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S

Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
Portable Multi Gas Detector, 4-Gas, LEL, O2, CO, H2S
from
$828.16
Ex Tax: $828.16
  • Stock: In Stock
  • Model: GD200-M4
  • Weight: 1.00
  • SKU: GD200-M4

Available Options

Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.

High cost-effective multi gas detector is used for monitoring 4 gas concentration of LEL, O2, CO, and H2S, widely applicable for tunnels, tube well, laboratory, and other confined spaces.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof.

Specification

ModelGD200-M4
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry (O2, CO, H2S), Catalytic combustion (LEL)
GasLEL, O2, CO, H2S
Range (Optional)*CO: 0-500/1000/2000ppm, H2S: 0-100/200ppm, O2: 0-25% VOL/0-30% VOL, LEL: 0-100% LEL
ResolutionCO: 1ppm, H2S: 0.1ppm, O2: 0.1% VOL, LEL: 1% LEL
Accuracy≤±3% F.S.
Responce Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
CommunicationMini USB interface supports standard MODBUS communication protocol
Explosion-proof GradeⅡ 2G Ex ia Ⅱ CT4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note: We also provide other common gas detectors, and you can refer to RDDLZ Gas Detector Catalog to get the specific gas type and measurement range. If you have any questions, please feel free to contact us.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Tips: Service Life of Gas Detector

A gas detector is mainly composed of a sensors, circuit board and other components. It can be divided into two main parts, that is, the first part is the sensor part, and the second part is the body part of the detector, so for the service life of equipment, we also need to tell based on the two parts of the gas detector.

Let's look at the sensor in the gas detector first. The sensor has a fixed service life. The service life of the sensor varies with different principles. For example, the electrochemical sensors are usually designed for two-year service life and it has to be replaced when it expires. The replacement time is generally not related with use times and storage time, because the electrochemical sensor has the electrolyte at its internal which will naturally reduce in the process of the placement of the sensor even if you don't use it. Basically, it has a fixed replacement cycle, so it must be replaced once it comes due. It is suggested that it is unnecessary to prepare a sensor in advance in the use of gas detector, otherwise it is a kind of waste and loss.

The second part is the circuit board of the gas detector. From this point of view, generally a reliable designed circuit board with sufficient materials can guarantee the service life of the detector body for 3-5 years. Of course, we also refer to normal use, without rough operation, discarding and other bad and irregular preservation and operation. Some portable gas detectors include suction pumps and batteries that last about two years.

As for the service life of the gas detector, generally speaking, there will be no problem with the circuit board under normal use. In most cases, it is the sensor failure that causes the instrument failure. Therefore, the service life of the gas detector is equal to the service life of the sensor. The service life of the electrochemical sensor is about 2 years. After 2 years, the performance of the instrument needs to be tested and the sensor needs to be replaced.

Write a review

Note: HTML is not translated!
Rating
Bad Good

Builder in Product TAB

NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules. Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.