PTFE PH Electrode For Strong Acid And Alkali
from
$179.92
Ex Tax: $179.92
- Stock: In Stock
- Model: RDDLZ-PHELE-5013A
- Weight: 1.00
- SKU: RDDLZ-PHELE-5013A
Available Options
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
PTFE pH electrode can be used in harsh environment, such as strong acid and strong alkali.
Function:
- Special for strong acid and alkali, good corrosion resistance.
- Low impedance glass sensitive film.
- More accurate and stable measurement data.
- High-quality low-noise cable, can achieve 60m long distance signal transmission.
Specification:
Model | RDDLZ-PHETE-PH5013A |
Weight | 1kg |
Dimension | Length: 158mm, diameter: 25.4mm |
Measuring range | 0-14pH |
Accuracy | 0.02pH |
Temperature range | 0-60℃ (32-140℉) |
Temperature compensation * | Internal temperature sensor (NTC 10K) |
Zero position | 7±0.3pH |
Compressive strength | 0.6MPa |
Response time | 15s |
Installation size | 3/4NPT in both ends |
Shell material | PTFE |
Connection | Direct lead |
Cable length * | 5m/10m/15m, or other length less than 50m (need customization) |
Service life | 6 months |
The pH electrod installation methods:
1. Side wall installation (*The pH electrode must be at an angle of 15 degrees to the liquid surface. Otherwise, it will affect the normal use of the pH electrode.)
2. Flange mounted at the top
3. Pipe installation
4. Top installation
5. Submersible installation
6. Flow-through installation
Tips: PTFE electrode dosing system
- The electrode should be installed in the bypass beside the main pipe, and a valve should be installed at its front end to control the flow velocity. The flow shall be as small as possible, generally, as long as the outlet has a stable aqueous solution drops. Electrodes should be installed vertically and go deep into active water, and the water outlet should be higher than the water inlet to ensure that the electrode is completely immersed in the solution.
- The electrode should be calibrated before installation.
- As the measurement signal is a weak electrical signal, its acquisition cable should be independent and avoided to be connected in a same cable connector or terminal with the power line and control line, so as to avoid interference or breakdown of measuring units.
- When measuring cables need to be lengthened, please choose to customize the length or contact customer service (more than 15m).
Builder in Product TAB
NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc.