Your Cart
We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.
Free shipping all orders over on $200
30 days easy and hassle-free returns
24/48h Customer support available

Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol

Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
Fixed Oxygen (O2) Gas Detector, 0 To 25% / 30% Vol
from
$434.77
Ex Tax: $434.77
  • Stock: In Stock
  • Model: GD300-O2
  • Weight: 1.00
  • SKU: GD300-O2

Available Options

Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.

Fixed oxygen gas detector for sale. Optional measuring range 0~25% or 0~30%, output signal 4-20mA & RS485. The O2 gas detector can 24 hours online for oxygen concentration detecting, supports remote control, sound and light alarm, affordable price, reliable manufacturer.

Features

  • Oxygen gas detector adopts high precision sensor for accurate gas leak detection.
  • Oxygen gas detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • The O2 gas detector is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • The oxygen gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • The O2 gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-O2
Detection PrincipleElectrochemistry
GasOxygen (O2)
Range (Optional)0-25% VOL, 0-30% VOL, 0-100% VOL
Resolution0.01% VOL (0-25/30% VOL), or 0.1% VOL (0-100% VOL)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 24V 100mA) for one alarm (default), or two groups of relay output (2NO+2NC, 24V 100mA) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeⅡ 2G Ex ia Ⅱ CT4 Ga
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12-36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
AccessoriesPower adapter: Input 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug or UK plug)

Note: To measure confined spaces such as pipelines, please contact us and inform the detailed conditions of use.

Fixed Oxygen (O2) Gas Detector Dimension (Unit: mm)

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Tips: Why you need an oxygen gas detector?

Oxygen detection is very important for entering confined spaces and entering certain open spaces below the ground. Other gases with higher density than air (such as gasoline, hydrogen sulfide, etc.) will accumulate in the downward direction, thereby displacing O2 in the space. There are two concentration points to consider in the detection of oxygen concentration: one is that too low O2 concentration will cause suffocation, and the other is that excessive oxygen exceeding the constant may cause unimaginable acceleration and enhancement of combustion or other chemical reactions. The concentration of oxygen in normal air is about 20.9%, and the balance (over 78%) is mainly nitrogen, and the rest includes a small amount of water vapor, carbon monoxide and other gases.

Most confined space standards and law enforcement agencies, such as OSHA, use the volumetric concentration of O2 to determine whether it is insufficient, and the usual lower limit is 19.5%. This is also the lowest alarm point set by most manufacturers on the oxygen gas detector. Some law enforcement agencies also use partial pressure of gas instead of concentration to indicate insufficient oxygen. In this case, if the O2 partial pressure is lower than 16.3 kPa or 122 mHg, it is deemed insufficient (16 kPa oxygen partial pressure is approximately equivalent to 16.3% oxygen concentration at sea level). The reason for using partial pressure is that the human body relies more on oxygen partial pressure rather than concentration for breathing.

Write a review

Note: HTML is not translated!
Rating
Bad Good

Builder in Product TAB

NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules. Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.