Your Cart
We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.
Free shipping all orders over on $200
30 days easy and hassle-free returns
24/48h Customer support available

75L Steam Autoclave Sterilizer

75L Steam Autoclave Sterilizer
75L Steam Autoclave Sterilizer
from
$5,308.33
Ex Tax: $5,308.33
  • Stock: In Stock
  • Model: RDDLZ-SAS-75L
  • Weight: 1.00
  • SKU: RDDLZ-SAS-75L

Available Options

Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.

220V vertical autoclave sterilizer machine with a capacity of 75L , has self-expanding sealing ring, excellent sealing effect. 4.5kW autoclave sterilizer is designed with LED digital display , and more accurate temperature control.

Features

  • Manual control: Vertical steam sterilizer uses a handwheel control system for easy operation. The user can adjust the handwheel manually to control the steam pressure and temperature, as well as the processing time. This manual control makes operation more intuitive and reliable.
  • Multiple capacities and specifications: Vertical autoclave offers a wide selection of capacities and specifications to meet the needs of different users. Depending on the need, the appropriate size can be selected to accommodate different sizes and quantities of items to be sterilized.
  • Safe and reliable: Vertical autoclave high pressure steam sterilizer is usually equipped with multiple safety protection devices, such as safety valves, pressure sensors and temperature sensors, to ensure the safety of the operation process. When the set pressure and temperature limits are reached, the protection mechanism is automatically activated to prevent accidents such as overheating or explosion.
  • Strong durability: This type of equipment is usually made of high-quality stainless steel material with good corrosion resistance and durability. Its structure is sturdy and reliable, able to withstand long periods of high temperature and high pressure use, reducing the frequency of equipment maintenance and replacement.

Specifications

ModelRDDLZ-DGL-75B
Input voltage AC220V ± 22V
Frequency50Hz ± 1Hz
Power4.5kW
Display methodLED digital tube/pressure gauge
Volume75 ± 5L
Capping methodHandwheels
Rated working  temperature134℃
Rated working pressure0.22Mpa
Sterilization chamber specificationsФ400×625mm
Sterilization chamber thickness2mm
Inner cylinder thickness0.8mm
Warming time RT-134℃within 40min
Sterilization time4-120min
Net/Gross weight90kg/120kg
Product size525×525×1200mm

Note : 220V vertical sterilizer, without plug, needs to be wired by yourself.

Applications

 

Details

Tips: What is steam autoclave sterilizer operation precautions?

  • Read the instruction manual carefully: Before operation, be sure to read the instruction manual of the equipment carefully. Understand the functions, operating procedures and safety precautions of the equipment to ensure correct operation.
  • Ensure the condition: Before use, check that the equipment is in good condition and ensure that all parts and connections are working properly. If any damage or malfunction is found, stop using it and contact the supplier for repair or replacement.
  • Select the correct capacity and load: Select the appropriate capacity and load according to the size and quantity of the items being processed. Do not overload the equipment as this may affect the sterilization effect and the life of the equipment.
  • Prepare treated items: Ensure that treated items meet applicable sterilization specifications and preparation requirements. When cleaning and preparing items, follow proper cleaning procedures and make sure to remove dirt and residues that may affect sterilization results.
  • Place items correctly: Place items to be processed correctly in the sterilization chamber, avoiding stacking or blocking between items to ensure that steam has full access to each item surface.
  • Controlling pressure and temperature: Adjust the pressure and temperature of the equipment according to the needs of the items being treated. Use a handwheel or other control device and follow the instructions in the equipment manual to avoid exceeding safety limits.
  • Ensure adequate air venting: Ensure that the air inside the equipment is adequately vented before the sterilization process begins. Before starting sterilization, open the exhaust valve until all air is exhausted and vented as steam.
  • Ensure safe operation: During operation, follow the equipment's safe operating procedures. Do not force the lid open or terminate the sterilization process unless the operating requirements in the equipment manual are met. Avoid contact with hot surfaces and use heat protective gloves and other personal protective equipment.

Write a review

Note: HTML is not translated!
Rating
Bad Good

Builder in Product TAB

NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules. Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.