Your Cart
We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.
Free shipping all orders over on $200
30 days easy and hassle-free returns
24/48h Customer support available

2 Ton Air Cooled Industrial Water Chiller

2 Ton Air Cooled Industrial Water Chiller
2 Ton Air Cooled Industrial Water Chiller
2 Ton Air Cooled Industrial Water Chiller
2 Ton Air Cooled Industrial Water Chiller
2 Ton Air Cooled Industrial Water Chiller
from
$4,595.38
Ex Tax: $4,595.38
  • Stock: In Stock
  • Model: RDDLZ-IWC-2TON
  • Weight: 1.00
  • SKU: RDDLZ-IWC-2TON

Available Options

Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.
Create unlimited custom product blocks and display them in accordions or tabs or open blocks. Each block can be assigned to all products at once or specific products according to advanced criteria.

Small industrial 2-ton water chiller with air-cooled design, offering single-phase 220V and three-phase 380V options, perfect for factories, workshops, and industrial equipment. With 2525W input power and a max lift of 52 meters, dual temperature control, and compressor overcurrent protection.

Specification

ModelRDDLZ-JL-8300
Refrigeration Capacity2 ton
Voltage (Optional)Single phase 220V (50Hz/60Hz), three phase 380V (50Hz)
Current2.7-17.5A
Input Power2525W
Pump Voltage / Power220V AC / 750W
Cooling TypeAir cooled
Max. Lift52M
Max. Flow3m3/h
Refrigerant TypeR401A
Inlet/Outlet Port1/2" Internal Thread
Max. Capacity of Tank45L
Alarm DeviceOver-temperature alarm, flow alarm
Machine Dimension610*580*1110mm
Net Weight / Gross Weight105kg / 118kg


Features

  • Air-cooled industrial water chiller offers a cooling capacity of up to 2 tons.
  • Equipped with a dual digital display, it shows both set and real-time temperatures at a glance.
  • It supports full-power and micro refrigeration modes, adapting to a wide range of working conditions.
  • Intelligent and constant operation modes ensure stable performance across various temperature environments.
  • High-precision temperature control keeps fluctuations within ±0.5 ℃.
  • Built-in over-temperature alarm and sensor self-diagnosis enhance safety and reliability.
  • The unit also features compressor over-current protection and water flow alarms.
  • An anti-freeze function safeguards waterway components in low-temperature environments.

Shipping Way of RDDLZ Water Chiller

*Just confirm the shipping way by email when you place your order.

1. Shipping by Air: Since the compressed refrigerant inside the chiller is considered hazardous and may explode, it must be released before transport. This means the chiller will be shipped without refrigerant. Once the machine arrives at your location, a local professional can easily add refrigerant, just like refilling a standard air conditioner. Estimated delivery time: 15–30 days.

2. Shipping by Sea: Delivery takes longer, approximately 40–55 days, but the chiller comes pre-filled with refrigerant, so no additional charging is needed upon arrival.

Tips: What is the Common Problem with the Air-cooled Water Chiller?

A common problem with air-cooled water chillers usually stems from their reliance on ambient air for heat rejection. The main issues include:

  1. Dirty or clogged condenser coils: Dust, debris, or leaves can block airflow, reducing cooling efficiency and causing the chiller to overheat.
  2. Insufficient airflow: Fans may fail or operate at reduced efficiency, leading to poor heat dissipation.
  3. Refrigerant issues: Leaks, overcharge, or undercharge can decrease cooling capacity and increase energy consumption.
  4. Compressor problems: Wear, electrical issues, or improper lubrication can lead to compressor failure or inefficient operation.
  5. High ambient temperatures: Air-cooled chillers lose efficiency in hot weather since the condenser relies on outside air to reject heat.
  6. Water flow issues: Low flow or pump problems in the chilled water loop can trigger freeze protection or reduce cooling output.
  7. Scaling and fouling in water circuit: Even though the condenser is air-cooled, the water loop may still accumulate scale or sediment, reducing heat transfer.

Write a review

Note: HTML is not translated!
Rating
Bad Good

Builder in Product TAB

NEW! Since Journal 3.2, the much improved T.A.B (Tabs Accordion Blocks) system supports the page builder inside the tab content. Unlimited Blocks, Tabs or Accordions with any HTML content or the builder interface (supporting custom rows/columns/modules) can be assigned to any individual product or to certain groups of products, like entire categories, brands, products with specific options, attributes, price range, etc. You can indicate any criteria via the advanced product assignment mechanism and only those products matching your criteria will display the modules. Also, any module can be selectively activated per device (desktop/tablet/phone), customer login status and other criteria. Imagine the possibilities.